Biomedical Implants from Metal Foam with Similar Elasticity to Bone

Author: North Carolina State University
Published: 2010/02/16
Topic: Prostheses / Prosthetics - Publications List

Page Content: Synopsis - Introduction - Main

Synopsis: Metal foam that has a similar elasticity to bone could mean a new generation of biomedical implants.

Introduction

New material mimics bone to create better biomedical implants - A metal foam that has a similar elasticity to bone could mean a new generation of biomedical implants that would avoid bone rejection that often results from more rigid implant materials, such as titanium.

Focus

Researchers at North Carolina State University have developed the metal foam, which is even lighter than solid aluminum and can be made of 100 percent steel or a combination of steel and aluminum.

In a new paper, researchers have reported recent findings that, in addition to the extraordinary high-energy absorption capability and light weight of their novel composite foams, the "modulus of elasticity" of the foam is very similar to that of bone. Modulus of elasticity measures a material's ability to deform when pressure is applied and then return to its original shape when pressure is removed. The rough surface of the foam would also foster bone growth into the implant, improving the strength of implant.

Modulus of elasticity, which is measured in gigapascals (GPa), is extremely important for biomedical implants, explains Dr. Afsaneh Rabiei, an associate professor of mechanical and aerospace engineering and an associate faculty member of biomedical engineering at NC State and co-author of the paper.

"When an orthopedic or dental implant is placed in the body to replace a bone or a part of a bone, it needs to handle the loads in the same way as its surrounding bone," Rabiei says. "If the modulus of elasticity of the implant is too much bigger than the bone, the implant will take over the load bearing and the surrounding bone will start to die. This will cause the loosening of the implant and eventually ends in failure. This is known as "'stress shielding.'" When this happens, the patient will need a revision surgery to replace the implant. Our composite foam can be a perfect match as an implant to prevent stress shielding," Rabiei explains.

To give an idea of the difference between the modulus of elasticity of bone and that of traditional implants, bone has a modulus of between 10 and 30 GPa - while titanium has a modulus of approximately 100 GPa. The new composite foam has a modulus that is consistent with bone, and is also relatively light because it is porous.

The rough surface of the metal foam, Rabiei says, "will bond well with the new bone formed around it and let the body build inside its surface porosities. This will increase the mechanical stability and strength of the implant inside the body."

The research, "Evaluation of modulus of elasticity of composite metal foams by experimental and numerical techniques," was funded by the National Science Foundation and will be published in the March issue of Materials Science and Engineering A. The research was co-authored by Rabiei and former NC State Ph.D. student L. Vendra.

"Evaluation of modulus of elasticity of composite metal foams by experimental and numerical techniques"

Authors: L. Vendra, Afsaneh Rabiei, North Carolina State University

Published: March 2010, Materials Science and Engineering A

Abstract: The elastic behavior of Al-steel composite metal foams developed by casting technique was characterized by evaluating the modulus of elasticity through compression experiments, constitutive scaling equations and 2D finite element modeling. Experiments showed an elastic modulus of 10-12 GPa for Al-steel composite foams while the scaling laws predicted 3.5 GPa and 30 GPa as the lower and upper bounds of modulus of elasticity respectively. Two-dimensional finite element models of composite foams developed and analyzed assuming perfectly elastic materials, resulted in an elastic modulus of 10 GPa which is in good agreement with the experimental results.

Explore Similar Topics

: A new surgical procedure enhances neural feedback from the residual limb, enabling patients to walk more naturally and navigate obstacles more effectively.

: Device allows amputees to sense and respond to temperature by delivering thermal information from the prosthesis fingertip to the amputee's residual limb.

Citing and References

Founded in 2004, Disabled World (DW) is a leading resource on disabilities, assistive technologies, and accessibility, supporting the disability community. Learn more on our About Us page.

Cite This Page: North Carolina State University. (2010, February 16). Biomedical Implants from Metal Foam with Similar Elasticity to Bone. Disabled World (DW). Retrieved May 24, 2025 from www.disabled-world.com/assistivedevices/prostheses/metal-foam.php

Permalink: <a href="https://www.disabled-world.com/assistivedevices/prostheses/metal-foam.php">Biomedical Implants from Metal Foam with Similar Elasticity to Bone</a>: Metal foam that has a similar elasticity to bone could mean a new generation of biomedical implants.

While we strive to provide accurate and up-to-date information, it's important to note that our content is for general informational purposes only. We always recommend consulting qualified healthcare professionals for personalized medical advice. Any 3rd party offering or advertising does not constitute an endorsement.